Event Indicator Area toward the top of the Monitoring System Display
Illustration 1 | g06600041 |
(1) Pop-up Event Message |
Illustration 2 | g06600050 |
(2) Event Icon List |
The Monitor will activate, display, and log events for machine conditions that are not within normal operating parameters. The Monitor will detect some of the events that are not within normal operating parameters. However, many of these events are detected by the other control modules on the machine.
The Monitor receives this event data from the other control modules via the Cat® Data Link. The level of the warning response will be determined depending on the severity of the problem. The event warnings are classified into three warning levels. The warning level determines which response is required by the operator. Warning Level 1 represents the least severe problem and Warning Level 3 represents the most severe problem. The warning levels, monitor response, and the required operator actions are given below.
Warning Level 1 - Graphic Display - requires operator awareness.
Warning Level 2 - Graphic Display and Action Lamp - requires a change in the operation of the machine or a change in the maintenance of the machine to correct the condition.
Warning Level 3 - Graphic Display, Action Lamp, and Action Alarm - requires immediate shutdown of the machine to prevent damage to the machine or personnel.
When multiple warnings are present in the system, the highest warning level is shown first. Press the arrow keys to view all the logged warnings. If no keys are pressed within 5 seconds, the display will return to the highest level warning.
Note: All the warnings that are listed may not be applicable to all machine models.
Warning Messages |
---|
Security System Active |
Security System Active (HESS) |
Operator Override Hot Shutdown |
Active Regen |
Key Off Regen |
Engine Cooldown Active |
Service Required |
Engine Fault Shutdown Safely |
Inlet Air Temp Power Derate |
Engine Oil Pressure Power Derate |
Fuel Filter Plugged Power Derate |
Coolant Temp High |
Hydraulic Oil Temp High |
DPF Level High Shutdown Safely |
Starter Over Heat |
ECM Error |
Quick Coupler Unlock |
100% Load |
Cancel Auto Stop |
Lift Overload Warning |
Limited Mobility Mode |
Engine Shutdown Pending |
Engine Shutdown Idle Time Exceeded |
Regen Disabled |
Engine Fault Check Engine |
Tool Control Malfunction |
DPF Level High Regen Required |
Engine Oil Pressure Low |
Battery Voltage Irregular |
Coolant Temp Power Derate |
Hydraulic Oil Temp Power Derate |
Hydraulic Return Filter Plugged |
Water Separator Full |
Attachment Filter Plugged |
Hydraulic Oil Temp High (Tool) |
Lever Is Not Neutral |
Cycle the Lock Lever |
90% Load |
Fuel Level Low |
Bucket Cylinder Stroke End |
Engine Over Speed Warning |
Fuel Pressure High |
Fuel Filter Plugged |
Intake Air Filter Plugged |
Coolant Level Low |
Engine Oil Level Low |
Hydraulic Oil Level Low |
Check Filter/Fluid Information |
Fasten Seat Belt |
Regen Condition Not Met |
Regen Condition Engine Temp Low |
Regen System Fault |
Glow Active |
Low Battery Elevated Idle |
Warmup Mode Power Derate |
Intelligent Hammer Active |
Reverse Fan Starting |
Quick Coupler Locking |
Verify Tool Locking |
Bucket In |
Deceleration Area |
Illustration 3 | g06223816 |
The Event Icon List displays all active events. The list orders the higher-level warnings first, with the red furthest left, and gray furthest right. The current selected icon will be highlighted with yellow bow surrounding the icon.
Arrows will appear at either side of the icon list if there are too many icons to display on a single bar. The arrow will navigate to the next set of icons instantly rather than the next icon from the bold one.