14L Motor Grader Inlet Module (Catalyst) - Remove and Install - Catalyst Caterpillar


Inlet Module (Catalyst) - Remove and Install - Catalyst
`
1.1. Removal Procedure
2.1. Installation Procedure

Removal Procedure

Start By:

  1. Remove hood enclosure.

Table 1
Required Tools 
Tool  Part Number  Part Description  Qty 
Loctite Nickel Anti-Seize Lubricant  

------ WARNING! ------

Hot engine components can cause injury from burns. Before performing maintenance on the engine, allow the engine and the components to cool.


------ WARNING! ------

Wear goggles, gloves, protective clothing, and a National Institute for Occupational Safety and Health (NIOSH) approved P95 or N95 half-face respirator when handling a used Diesel Particulate Filter or Catalytic Converter Muffler. Failure to do so could result in personal injury.




    Illustration 1g03502481

  1. Disconnect temp sensor (1).


    Illustration 2g03502482

  2. Disconnect tube assembly (2).


    Illustration 3g03502483

  3. Disconnect clamp assembly (3).


    Illustration 4g03502485

  4. Remove guard assembly (4).


    Illustration 5g03502486

  5. Disconnect strap (5). Loosen clamp (6). Remove inlet module (7).

Installation Procedure

Note: When installing a new inlet module (catalyst) or a cleaned inlet module (catalyst), a DOC reset must be performed. Refer to Special Instruction, REHS8180, "Aftertreatment Filter Maintenance on Tier 4 Final Products Equipped with a Diesel Particulate Filter (DPF), Diesel Oxidation Catalyst (DOC), and a Selective Catalyst Reduction (SCR) Filter" for the correct procedure.

  1. Install inlet module (7) in the reverse order of removal.


      Illustration 6g03514927
      Facing the Inlet Module Assembly.

    1. Install clamp (5) to Dimension (Y). Dimension (Y) is 30° ± 5°. Tighten clamp (5) to a torque of 60 ± 5 N·m (44 ± 4 lb ft).


      Illustration 7g03514928
      Typical Example

      Note: Do not use power tools in order to torque strap (6).

    2. Apply Tooling (A) to the threads of strap (6) along Distance (Z). Distance (Z) is 25 mm (1.0 inch) above the trunnion. Tighten strap (6) to a torque of 15 + 3 - 0 N·m (133 + 27 - 0 lb in).


      Illustration 8g03514935
      Cutaway view of band clamp (3) in position on the assembly.

      Note: Do not use power tools in order to torque band clamp (3).

    3. Verify that the cup of the Ball Joint (G) does not touch the radius of the Ball (F). Position band clamp (3) and hand tighten band clamp (3). Band clamp (3) should be in the center of the joint.

    4. Dimension (D) and Dimension (E) should be equal within 2.0 mm (0.08 inch). Repeat the measurements every 90° around band clamp (3). If necessary, adjust band clamp (3).

    5. Torque band clamp (3) to a torque of 35 ± 2 N·m (26 ± 1 lb ft).

    6. Apply Tooling (A) to the threads of temperature sensor (1). Tighten temperature sensor (1) to a torque of 45 ± 5 N·m (33 ± 4 lb ft).

Information System: